Business customers » Products and standards

Products and standards

This webpage is dedicated to Barwon Water's product, material and design standards.

The information is intended:

  • product suppliers and vendors
  • construction and engineering designers and contractors.

This page includes:

  • our product catalogues for non-pressure and pressure pipeline systems
  • references to our infrastructure standards
  • an application for authorisation of new products
  • standard drawings.

 

We  provide detail on products, materials and standards approved for use in our infrastructure projects.

Approved products and materials

Barwon Water has adopted the approved products catalogue developed by City West Water with some limitations and exceptions (see supplementary catalogues, below).

You can search for City West Water-approved products on the Melbourne Retail Water Agencies (MWRA) product portal.

  Melbourne Retail Water Agencies (MWRA) product portal

 


 

Supplementary catalogues

Our supplementary catalogues define the limitations and exclusions between products approved for use with City West Water and those approved by us.

  Supplementary product catalogue for pressure pipeline systems PDF 969 KB

  Supplementary product catalogue for non-pressure pipeline systems PDF 1.35 MB

 

Note, there are no supplementary catalogies for the following:

Meters and ancillary components: all products listed with City West Water are also approved for use at Barwon Water.

Sewerage pumping stations: none of the products approved by City West Water are approved for use at Barwon Water. Requirements for sewerage pumping stations are outlined in Barwon Water's supplementary information to the WSAA Sewerage Pumping Station Code of Australia.

  Supplement to the WSAA Sewerage Pumping Station Code of Australia PDF 111 KB

 

How to use the product catalogues

To check if a product is approved for use by Barwon Water:

  1. Search the MRWA product portal to check that the product is approved by City West Water
  2. Refer to the relevant supplementary catalogue for limitations (section 1) or exclusions (section 2). 

 


 

Approval of new products

Suppliers and vendors can apply to have new products approved by Barwon Water.

We will only consider new products that:

  • fulfil an infrastructure need, and
  • have received a positive appraisal from the Water Services Association of Australia (WSAA) or one of the Melbourne metropolitan water retailers (City West Water, Yarra Valley Water or South East Water).

We will only appraise new products that fulfill these criteria and we may conduct field trials. We may also elect to direct the application to WSAA for an appraisal.

To apply for a new product approval, please use the form below.

  Application for product approval  PDF 139 KB

  


  

Standard drawings

These drawings are provided for contractors and consultants to ensure that all work is carried out to agreed, common standards for design, engineering and construction.

New and revised drawings will be added to this webpage as they are approved.

  Number  Name Approved File size
PDF C001-R0 Existing concrete wall pipe penetration and encasement detail 11/09/2014 PDF 550 KB
PDF C010-R0 Pipe supports: steel (vertical loads only) types 1 to 5 11/09/2014 PDF 900 KB
PDF C017-R0 Pit cover: hinged grid mesh (aluminium) 11/09/2014 PDF 603 KB
PDF C020-R0 Pit covers for circular pits: aluminium and mild steel 11/09/2014 PDF 490 KB
PDF G010-R0 Chain wire railless security fence 11/09/2014 PDF 836 KB
PDF G011-R0 Post and wire fence 11/09/2014 PDF 603 KB
PDF G012-R0 Post and wire fence: gate details 11/09/2014 PDF 449 KB
PDF G020-R0 Steel and timber bollards 11/09/2014 PDF 507 KB
PDF G021-R0 Valve and hydrant identification markers and marker posts 11/09/2014 PDF 979 KB
PDF G022-R0 Access and rescue buoy anchor stanchion: typical details 11/09/2014 PDF 819 KB
PDF J001-R0 Piping and instrumentation diagram: legend 11/09/2014 PDF 1.7 MB
PDF J003-R0 Piping and instrumentation diagram: monitoring and control schematic 11/09/2014 PDF 970 KB
PDF S021-R0 Rung ladder attached to wall: step-through and side-step ladder 12/02/2015 PDF 881 KB
PDF S022-R0 Vertical rung ladder extension stanchion 11/09/2014 PDF 747 KB
PDF S023-R0 Rung ladder attached to platform: step-through ladder 11/09/2014 PDF 873 KB
PDF S024-R0 Step ladder — flat bar stile type: elevation and typical details 11/09/2014 PDF 983 KB
PDF S025-R0 Step Ladder — parallel flange channel stile type: elevation and typical details 11/09/2014 PDF 963 KB
PDF W001-R0 Pipelines — trench and backfill: typical details 11/09/2014 PDF 1.3 MB
PDF W004-R0 Flowmeter pit: layout and details 11/09/2014 PDF 576 KB
PDF W010-R0 Water supply scour valve installation: type A 11/09/2014 PDF 554 KB
PDF W011-R0 Water supply scour valve installation: type B 11/09/2014 PDF 588 KB
PDF W012-R0 Water supply line valve with scour valve bypass 11/09/2014 PDF 836 KB
PDF W013-R0 Water reclamation line valve installation with scour valve 11/09/2014 PDF 719 KB
PDF W020-R0 Water supply air valve details: type A and B (non-trafficable) 11/09/2014 PDF 626 KB
PDF W021-R0 Water supply air valve details: type C and D 11/09/2014 PDF 848 KB
PDF W022-R0 Water supply air valve details: type E and F (non-trafficable) 11/09/2014 PDF 701 KB
PDF W023-R0 Water supply line butterfly valve installation with air valve 11/09/2014 PDF 990 KB
PDF W024-R0 Water reclamation air valve: typical details 11/09/2014 PDF 817 KB
PDF W025-R0 Water supply line gate valve installation with air valve 11/09/2014 PDF 669 KB
PDF W030-R0 Water supply flange arrangement details 10/07/2014 PDF 206 KB